Conversion factor from dosemeter reading to air kerma for nuclear worker using anthropomorphic phantom for further conversion from air kerma to organ-absorbed dose

古田 裕繁*; 辻村 憲雄; 西出 朱美*; 工藤 伸一*; 三枝 新*

Radiation Protection Dosimetry, 189(3), p.371 - 383, 2020/05

 被引用回数:4 パーセンタイル:44.4(Environmental Sciences)

Estimation of cancer risk based on the organ-absorbed dose is underway for the Japanese Epidemiological Study on Low-Dose Radiation Effects (J-EPISODE). The reconstruction method for the organ-absorbed dose follows the approach adopted in the IARC 15-Country Collaborative Study, which examined the dosemeter response to photon exposure for the old film badge (FB) type, a multi-element FB and a thermoluminescence dosemeter. Until 2000, the dosemeters used in Japan were almost the same in the IARC study, so IARC study data could be used as they were. However, since 2000, the type of dosemeter has been replaced with active personal dosemeters (hereafter called electronic personal dosemeters), radio-photoluminescent glass dosemeters (Glass badge) and optically stimulated luminescence dosemeters (Luminess badge). Hence, it was necessary to collect these data again. A dosemeter response experiment was conducted using a device that irradiated an anthropomorphic phantom in the Japan Atomic Energy Agency calibration laboratories. The aim of the paper is to provide a conversion factor from reading in terms of $$H_{rm p}$$(10) to air kerma for realistic conditions for further conversion from air kerma to organ-absorbed dose. The obtained dosemeter responses for the dosemeter types currently used in Japan were consistent with those in the IARC study. These data will be utilized for J-EPISODE in reconstructing the organ-absorbed dose.

論文

Performance of Panasonic ZP-1460 electronic personal dosemeter under exposure conditions likely to be found at Fukushima Daiichi Nuclear Power Plant

辻村 憲雄; 吉田 忠義; 星 勝也; 百瀬 琢麿

JPS Conference Proceedings (Internet), 11, p.070008_1 - 070008_6, 2016/11

A study on the performance of the Panasonic ZP-1460 electronic personal dosemeter, the model used in the aftermath of the Fukushima Daiichi Nuclear Power Plant accident in March 2011, was conducted under actual exposure situations likely encountered in the plant. The tests pertained to (1) the dose rate response over dose rates $$>$$100 mSv/h and (2) the angular response on an anthropomorphic phantom exposed to the rotational and isotropic irradiation geometries. The test results confirmed that the dosemeter provides H$$_{p}$$(10) as a reasonably close estimate of the effective dose for any exposure geometries. The dosemeter response data evaluated in this study can be utilized for converting dosemeter readings to the absorbed dose to any organs and tissues for epidemiologic purposes.

報告書

3$$^{11}$$$$phi$$球形NaI(Tl)シンチレーション検出器の実効線量当量評価用G(E)関数(スペクトル-線量交換演算子)

堤 正博; 森内 茂; 斎藤 公明

JAERI-M 89-196, 30 Pages, 1989/11

JAERI-M-89-196.pdf:1.57MB

国内法令に国際放射線防護委員会の考え方が取り入れられ、実効線量当量が導入された。この実効線量当量を評価するめに、波高スペクトルからの線量換算が容易にしかも高精度にできるスペクトル-線量変換演算子、G(E)関数を決定した。検出器は3$$^{11}$$$$phi$$球形NaI(Tl)シンチレーション検出器で、測定する$$gamma$$線のエネルギーは40KeVから3MeVまでである。照射ジオメトリー別に5種の実効線量当量用G(E)関数を示した。ここでは、人体形状ファントムを用いたモンテカルロ計算から得られた線量値データに基づいて導出された。なお、比較評価のために、球ファントムにおける1cm線量当量および空気吸収線量に対するG(E)関数も併せて示した。

口頭

様々な$$gamma$$線入射ジオメトリにおける電子式個人線量計の指示値と臓器線量の関係

辻村 憲雄; 星 勝也; 百瀬 琢麿

no journal, , 

外部放射線被ばくの防護においては、体表面に付けた個人線量計で実測した実用量をもって実効線量などの防護量の代替とする管理が一般に行われる。しかしながら、事故時の線量評価や疫学調査においては、その線量計の指示値を臓器線量に関連付けて解釈するなどの必要がある。そこで、福島第一原子力発電所事故の際に構内で使用されていたものと同じ型式の電子式個人線量計について、人体形状ファントム上での$$gamma$$線に対する応答特性を調べ、指示値と臓器線量の関係を調べたので報告する。

口頭

理想的な照射条件と点線源を用いる近似照射条件における光子用個人線量計レスポンスの相違の評価; 人体形状ファントムでのモンテカルロ計算結果

辻村 憲雄

no journal, , 

事故時の線量評価や疫学調査では、実用量で校正された個人線量計の指示値を実効線量等に変換して分析する必要がある。その目的で、人体形状ファントムに取り付けた個人線量計を、作業場における代表的な曝露ジオメトリを模擬する条件で照射し、そのレスポンスを実験的に評価する試みが行われている。理想的なAP, ROT, ISO照射条件と、点線源を用いたそれらの近似条件(距離を変えて)について、人体形状ファントム上における個人線量計レスポンスをモンテカルロ計算によって比較した結果、最大4%の系統的なズレが確認された。